Designed to complete dosimeter-radiometer DKC-96, variant DKC-96Bk (detection unit BDZB—96k + UIK-05 or UIK-06). An automatic compensation of the level of own and external radiation background is used in the detection unit

Detection unit is used for measurement of beta-radiation flow density of sources with radionuclides  90Sr + 90Y,204Tl, 14C.

Range of measurement of beta-radiation flow density of sources with radionuclides  90Sr + 90Y, min-1·sm-2

from 1 to 10000

Sensitivity of 90Sr + 90Y , impc-1 for 1 min-1sm-2

0,3

Range of energies of the registered beta-radiation , MeV

from 0,12 to 3,0

Minimum duration of measuring

5 s

Basic relative error in the dosimeter- radiometer

± (20+250/Ах), where Ах – is a numeral value of the measured value

Efficiency of registration, %

– of radionuclides 90Sr + 90Y

– of radionuclide 204Tl

– of radionuclide 14C

45

23

3,0

Type of detector

Gas-discharge Geiger-Muller counter

Automatic compensation of the level of own and external radiation background

Gas-discharge Geiger-Muller counter

Area of the active surface of the detector, sm2

30,0

Overall dimensions of the detection unit, mm

Ø88×110

Mass of the detection unit, kg

0,5

 

The detection unit is fastened to the extensible rod, which ensures conducting measurements at a distance of less than 1 m from the operator.